Vapor Pressure                

Automatic Mini Methods

80000-0 SETAVAP ANALYZER

80000.jpg (33149 bytes)   

(click on picture to enlarge)

ASTM D5188; D5191; IP 394; IP 409; EN 13016-1; EN 13016-2 Correlates with: ASTM D323; D2533; D4953; D5482; D6378; IP 69; IP 402; ISO 3007; 
EN 12; JIS K2258; NF M07-079

bullet

Automatic operation

bullet

Five vapor pressure modes, including Reid

bullet

Vapor-Liquid ratio mode

bullet

Selectable units

bullet

Integral printer

bullet

RS232 interface

bullet

Automated calibration

The 80000-0 Setavap Analyzer is a vapor pressure tester with a test pressure range of 0-600kPa and a temperature range from 25°C below ambient to 100°C. The instrument is fully automatic, including the septum change, sample draining, and print-out of test results.  The instrument features six modes of operation, including a Reid vapor pressure mode. In the vapor pressure modes, the operator can select single or multiple vapor pressure tests on a sample at static, ramping or stepped temperatures.  The vapor-liquid mode enables determination of the temperature which produces a pre-set pressure.
All functions are accessed via the membrane keypad/digital display, while audible and visual prompts advise the status of the instrument and progress of the tests. Test results along with time, date, and sample identity are output via the integral printer and RS232 port. Pressure can be presented in kPa, psi, kg/cm2, mbar, mmHg, or inHg.

Calibration is automated and can be carried out at full vacuum, atmospheric pressure, or high pressure. A calibration certificate can be printed out.

SUPPLIED WITH: 5ml syringe, 3 needles, septum strips, paper/ink package, flask, mains lead and instruction manual.

Note: Seta 22422-6 Vacuum Pump is required for operation

ACCESSORIES

22422-6 VACUUM PUMP
80001-0 GAS-TIGHT SYRINGE, 1ml ±1%, for ASTM D5188
80003-0 TRANSFORMER, for use where electrical supply falls below 105V.
93700-0 LABORATORY REFRIGERATOR
80005-0 PRESSURE CALIBRATOR, recommended for recalibrating when testing above 200kPa.
99910-0 PORTABLE DIGITAL BAROMETER, 750 to 1150 mbar absolute
80007-0 VACUUSTAT MCLEOD GAUGE

 

81000-2 SETAVAP 2

81000cut.jpg (69649 bytes)   

(click on picture to enlarge)

ASTM D5191; IP 394; IP 409 (37.8°C); IP 481; EN 13016-1; EN 13016-2; Correlates with: D323; D4953; D5482; D6378; IP 69; IP 402; ISO3007; EN 12; 
JIS K2258;
NF M07-079

bullet

Rapid Vapor pressure testing

bullet

Automatic testing

bullet

Automatic drain and purge

bullet

3ml sample size

bullet

Selectable units - kPa or psi

bullet

Results available as Ptot, DVPE, EPA, Crude, Pabs

bullet

Audible and on-screen prompts

bullet

Simple calibration

bullet

RS232 interface

The Setavap 2 is an automated instrument for the measurement of the vapor pressure of gasoline, solvents, light crude oils, and other similar products.  All functions are accessed via a two button keypad and a rotary control. The digital display leads the operator through the test sequence, displays the instrument status and the test results. An audible prompt is sounded when an action is required from the operator. A sample is injected through a septum into a fixed volume chamber that is maintained at 37.8 °C ± 0.1 °C. The vapor to liquid ratio is 4:1. The pressure is automatically measured at one minute intervals until three readings are within 0.1 kPa, which determines the end of the test.  Results can be displayed as total pressure (Ptot), dry vapor pressure equivalent (DVPE), EPA requirements, or Reid (crude) using pre-programmed correlation equations, and may be printed via the integral RS232 port and optional 81002-0 printer. A facility is included to allow two part tests (Pabs) to be conducted at 37.8 °C.

All valve operations are automated including sample draining and chamber venting and purging. The valves utilise solvent resistant Kalrez seals Calibration of temperature and pressure is automated and simple to carry out.

SUPPLIED WITH: septum holder, waste container, mains lead, and instruction manual.

Test Temperature: 37.8 °C (100°F) ±0.1°C
Test Pressure Range: 0 to 200kPa ±0.5kPa (resolution 0.1kPa)
Pressure Display: kPa or psi (user selectable)
Vacuum Requirement: better than 0.01kPa (abs)
Computer Interface: RS232C
Voltage: 115Vac or 220Vac (±15%) (switchable) 50/60Hz
Power: 70W
Size (HxWxD): 37 x 13 x 20cm
Weight: 3.5kg