Phone: 574/271-7020                     "Through Thick and Thin..."

Home Up D942 D943
Home
Up
D942
D943

 

15400-2 SETA OXIDATION STABILITY CONSOLE BATH

15400.jpg (287035 bytes)  (click on picture to enlarge)

ASTM D525-IP 40; ASTM D873-IP 138; BS 2000 Parts 40 and 138; EN 7536; ISO 7536; NF M07-012; NF M07-013; FTMS 791b 3352; FTMS 791b 3354; JIS K2287

bullet

Operating temperature 100°C

bullet

4 test stations

bullet

Cold-Plunge bath

bullet

Optional automatic pressure monitoring

bullet

Integral vessel charge system

bullet

Constant level device

Measures the induction period for oxygen in gasoline, and allows the weight of gum and residue in aviation fuel to be determined by direct weighing.  The Seta Oxidation Stability Console Bath comprises a heated water bath with reflux condenser, a cold water plunge tank for cooling test vessels after each test, and an integral system for charging oxidation vessels prior to test. Includes oxygen charging lead (15620-0). Pressure can be monitored automatically using a Seta Auto Oxidation Control Unit (Seta 15450-2) or manually using either a Portable Cambridge Pressure Recorder (Seta 15611-0) or an oxygen pressure gauge (Seta 15600-0).  The bath can accommodate up to four Oxidation Vessels.

Capacity:  60 litres
Fluid type: Water
Temperature: 100°C
Max no of test vessels:  4
Vessel charging:  200psi maximum
Vessel cooling:  Cold water
plunge tank
Voltage:  110/120V, 60Hz
or 220/240V, 50/60Hz 
Power:  3kW
Size:  (HxWxD): 134 x 85 x 77cm
 
Weight:  67kg

ACCESSORIES

REQUIRED

15802-0 SETA OXIDATION VESSEL, polished steel with hexagonal top closure and ‘O’ ring seal.  Complete with stem, needle valve, quick connection Schrader male coupling for oxygen charging, and fitting for a transducer, pressure transmitting capillary or pressure gauge. Fitted with safety burst disc assembly and discharge tube.  Stainless steel burst disc ruptures within 10ms at 1530kPa ±10%, fatigue life greater than 100,000 cycles up to 90% of max. pressure.
Certification
: Supplied with UKAS pressure test certificate.
15803-0 SETA VESSEL CLAMP, to hold vessels during
opening and closing. Can be fixed to a bench.
15805-0 SPANNER, for oxidation vessel.
15810-0 SETA LINER, borosilicate glass with cover, pack
of 3.

THERMOMETERS:

ASTM22C/IP24C or ASTM22F/IP24F
Other items which may be required include: Solvents,
Filtering crucible, Oxygen

OPTIONAL

15650-0 WATER PURIFIER, to minimize scale production.  Suitable for domestic water supply, 60L/hr max. flow. Comprises disposable cartridge with capacity for 960L soft water or 180L hard water.
99200-2 LABORATORY OVEN
99100-2 ANALYTICAL BALANCE
45001-0 SETAPLUS EXTENDED 12 MONTH WARRANTY

15450-2 SETA AUTO OXIDATION CONTROL UNIT

bullet

Simultaneous measurement of 4 test vessels

bullet

Automatic end-point detection

bullet

Simple two point calibration facility

bullet

RS232 port    

                                                                                                       wpe3.jpg (18315 bytes)

An automatic pressure monitoring system for use with 15400-2, but can be used with other suitable baths.  Comprises two digital pressure monitors (each capable of monitoring two vessels) with a membrane switch control panel. The unit can also be used to display oxygen pressure whilst charging vessels.  The control unit can be connected to a computer via an RS232 port, and the Seta OXS Software (supplied) used for automatic end point detection, induction period determination, data logging, and graphical/printed output functions. The maximum run time may be selected as either 24 or 96 hours.
SUPPLIED WITH: computer cable, adaptor and software.

ACCESSORIES

REQUIRED

15455-0 TRANSDUCER, complete with lead (1 required for each oxidation vessel). Supplied with test certificate.
15456-0 CALIBRATION PLUG, plugs into transducer input to indicate calibration accuracy of 15450-2.

OPTIONAL

15620-0 SETA OXYGEN CHARGING LEAD, for connecting oxygen supply to oxidation vessel when not using 15400-2 bath.

CALIBRATION, VERIFICATION & TRAINING

80005-0 PRESSURE CALIBRATOR, for recalibrating pressure monitors

 

For information on our solid block oxidation baths please call 574/271-7020 or email us at sales@lazarsci.com

Click here for information on the Seta Oxi-Cor oil/water bath to accommodate corrosion and oxidation test methods.