15550-2 SETA OXI-COR BATH

15550.jpg (174426 bytes)  (click on picture to enlarge)

IP112; IP 227; BS 2000 Parts 40, 112, 138 and 154; EN 2160; ISO 7536; DIN 51 811; FTMS 791b 3352; FTMS 791b 3354; FTMS 791b 5325; NF M07-012; NF M07-013; NF M07-015; JIS K2513; JIS K2276;
Accelerated Shelf Life Test for Dried Pet Food (Provisional)

bullet

Ambient to 150°C temperature range

bullet

4 test stations

bullet

Copper/Silver corrosion & oxidation tests

A stainless steel water or oil bath with a temperature range of ambient to 150°C, temperature controlled to ±0.1°C by a top mounted thermostir circulator with integral over-temperature and low fluid level protection devices.  The bath has four test stations. Each test station has a lid with a hook for suspending either a copper corrosion test vessel (11500-0) or a test tube support (11420-0). A test tube support can hold up to three test tubes (11590-0). Any combination of copper corrosion vessels and test tube supports may be used.  One or more of the four lids may be replaced by oxidation vessel 15802-0. Pressure in the vessel can be monitored automatically with a 15450-2 Auto Oxidation Control Unit (Option 1), or manually with a 15611-0 Portable Cambridge Pressure Recorder (Option 2), or a 15600-0 Oxygen Pressure Gauge (Option 3).  A Silver Corrosion Conversion Kit (11510-0) is available to convert test stations to hold Seta 11430-0 glassware.

SUPPLIED WITH: 4 lids and instruction manual.

Temperature stability: 

±0.5°C
Bath capacity:  35 litres
Heater power:  1500W
Water inlet nozzle:  10mm
Overflow drain:  10mm

Supply Voltage: 

110/120V, 60Hz or: 220/240V, 50Hz

Size (HxWxD):  41 x 45 x 33cm

ITEMS REQUIRED FOR EACH TEST

Seta No. Copper Corrosion  Silver Corrosion Oxidation Stability

Fuel Storage Stability

11241-0

X      

11420-0 & 11590-0
or 11500-0

X      
11430-0    X    
11440-0   X    
11450-0   X    
11460-0 X X    
11470-0 X      
11480-0 X X    
11510-0   X    
11530-0 X X    
11550-0 X      
11570-0 X      
11580-0 X      
15450-2     Option 1  
15455-0     Option 1  
15460-0     Option 2 Option 2
15600-0     Option 3 Option 3
15611-0     Option 2 Option 2
15620-0     Option 1 and 3 Option 3
15640-0     Option 2 Option 2
15802-0     X  
15803-0     X X
15805-0     X X
15810-0     X X
99100-2     X X
99200-0     X  
ASTM12C X X    
ASTM22C      X  
ASTM61C       X

ACCESSORIES

REQUIRED

Select according to method of test and referring to the table above

11241-0 SILICON CARBIDE PAPER, 105µm (150 grit FEPA), 28 x 23cm, pack of 50.
11420-0 SUPPORT, for copper corrosion tests (except natural gasoline and aviation fuels). Holds three test
tubes in bath, pack of 2.
11430-0 SILVER CORROSION GLASSWARE, comprises amber glass oil test tube, cold finger condenser with
glass hook for test strip and glass cradle.
11440-0 SILVER TEST STRIPS, 99.9% Ag. 19 x 12.7 x 3mm, supplied with material certificate, pack of 5.
11450-0 ASTM COLOR STANDARD, ASTM D1660; D3241/IP323.
11460-0 SILICON CARBIDE PAPER, 65µm (240 grit FEPA), 28 x 23cm, pack of 25.
11470-0 SILICON CARBIDE PAPER, 100 grit FEPA, 28 x 23cm, pack of 50.
11480-0 SILICON CARBIDE GRAINS, 105µm (150 mesh), 500g/pack, 5 packs.
11500-0 COPPER CORROSION TEST VESSEL, for natural gasoline and aviation fuels. Stainless steel, 'O' ring
sealed screw-top closure. Max working pressure 7 bar (100 lbf/in2).
11510-0 SILVER CORROSION CONVERSION KIT, converts 15550-2 for silver corrosion tests. Comprises six
support rings, water manifold, clips and tubing.
11530-0 SETA MULTI-STRIP VICE, holds up to five strips while polishing.
11550-0 COPPER TEST STRIP, 75 x 12.5 x 2.4mm, with material certificate, pack of 30.
11570-0 FLAT GLASS TEST TUBE, to protect strip during inspection, pack of 10.
11580-0 ASTM-IP COPPER STRIP CORROSION STANDARD CHART, aluminum, plastic encapsulated.
11590-0 TEST TUBE, 25 x 150mm, pack of 10.
15450-2 SETA AUTO OXIDATION CONTROL UNIT
15455-0 TRANSDUCER, one required per oxidation vessel. Supplied with lead and test certificate.
15600-0 SETA OXYGEN PRESSURE GAUGE.
15611-0 PORTABLE CAMBRIDGE PRESSURE RECORDER
15620-0 SETA OXYGEN CHARGING LEAD, oxygen supply to oxidation vessel. 1m long, Schrader quick
connect couplings, one end male, one end female.
15460-0 OXYGEN CHARGING AND PURGING KIT, contains oxygen charging lead and pressure gauge.
15640-0 SETA PRESSURE TRANSMITTING CAPILLARY, oxidation vessel to 15611-0 (one per vessel).
15650-0 WATER PURIFIER, to minimize scale production.
15802-0 SETA OXIDATION VESSEL (mandatory requirement for ASTM D525-IP40), polished steel, hexagonal
top closure with ‘O’ ring seal. Complete with stem, needle valve, quick connection Schrader male coupling for oxygen charging, and fitting for a pressure transmitting capillary or pressure gauge.  Stainless steel burst disc ruptures within 10ms at 1530kPa ±10%, fatigue life greater than 100,000 cycles up to 90% of max. pressure.
Certification
: Supplied with UKAS pressure test certificate.

15803-0 SETA VESSEL CLAMP, to hold vessels for opening and closing. Can be bench mounted.
15805-0 SETA SPANNER, for oxidation vessel.
15810-0 SETA LINER, borosilicate glass with cover, to fit into oxidation vessels, pack of 3.
94632-0 SILICONE BATH OIL 20 litres, for filling bath, for temperatures between 100 and 150°C, 2 required
94633-0 BATH OIL 20 litres, for filling bath, for temperatures up to 80°C, 2 required.
94635-0 BATH OIL, 20 litres, for filling bath, for temperatures between 80 and 120°C, 2 required.
99100-2 ANALYTICAL BALANCE
99200-2 LABORATORY OVEN for D873

THERMOMETERS:

ASTM12C/IP64C or ASTM12F/IP64F, ASTM22C/IP24C, ASTM22F/IP24F, ASTM61C/IP63C or ASTM61F

CALIBRATION, VERIFICATION & TRAINING

80005-0 PRESSURE CALIBRATOR, for recalibrating pressure monitors

Other items which may be required include:
For copper/silver corrosion tests:- Solvents, Stainless steel forceps, Sample containers