Flash Point, Smoke Point and Sustained Burning Multi Method Flash Point Tester
Multi
Flash 34100 shown with Pensky Martens Module Pensky-Martens (A and B Closed
Cup) Abel (Closed Cup and Equilibrium) Tag (Closed Cup) Cleveland (Open Cup) Small Scale Rapid Equilibrium
(Setaflash) Closed Cup EASE OF OPERATION MultiFlash operation is microprocessor controlled. A backlit alphanumeric / graphics display and control panel provides a simple user interface using 2 buttons and the Seta Multifunctional And Rotational Test (SMART) control feature. The SMART control is exceptionally easy to use for setting modes of operation, temperatures, parameters and calibration. PRECISE TEST RESULTS Platinum Resistance Thermometers are used exclusively throughout MultiFlash to ensure accuracy, reliability and robustness. Verification or re-calibration of all instrument parameters is simple but secure. WIDE TEST TEMPERATURE RANGE Electrical heating provides precise and reliable test temperatures for all modules. An integral cooling fan assists in preparing the instrument for the next test. Some modules also allow the use of an external coolant supply to enable sub ambient test temperatures, and to provide a fast cool down facility at the end of the test. INTERCHANGEABLE TEST MODULES Pensky Martens, TAG Closed Cup, Cleveland Open Cup and Small Scale Flash Methods MultiFlash test modules faithfully conform to the requirements of the appropriate test method. Changing the test module is straightforward and completed within a few minutes. The module locates into an "intelligent" base unit, that recognizes the module type and automatically sets up relevant test parameters and calibration data. Each module includes a DIPS pod (Dipping, Ignition, Pilot, Stirrer) containing the igniter dipping/sweeping mechanism, the gas and electric igniters, the electronic igniter pilot and a stirrer (if required by test method.) GAS OR ELECTRIC IGNITION OPTIONS Electric Hot wire or gas ignition sources can be selected from the control panel for all tests and modules. The unique quick-fit coaxial igniter comprises a gas jet in conformance with the requirements of the test method, and an electric hot wire, which also ignites the gas jet when required. The igniter is simple to change, low cost, and has a long service life. For electric ignition the instrument uses precision electronic control to ensure that the hot wire provides a constant ignition temperature and prevents premature failure. For gas ignition, an electrically controlled valve automatically switches the gas supply on, and the gas jet is ignited by the electric hot wire. An integral rechargeable butane canister is supplied, however provision is made for the use of an external gas supply if required. AUTOMATIC FLASH DETECTION Automatic flash detection for the closed cup modules is achieved using thermocouple technology which has proven to be most effective for all products including bio-diesels and those containing moisture. The Cleveland module is fitted with an ionizing ring flash / fire detector that has been universally proven and adopted for this open cup test. SIMPLE CONTROL FUNCTIONS At the beginning of the test the sample is placed in the cup and the lid is closed. The DIPS pod is brought into mechanical contact with the cup / lid assembly by a simple "push to engage" operation. A "start" control initiates the test and the status is continuously monitored with any problems or error conditions being shown on the display. AUTOMATIC RESULT At the end of the test
the result is displayed, an audible warning is given and the cup and associated
heating system are cooled down to
a user defined temperature. On the Cleveland module, a damper is deployed to
extinguish any flame in the cup.
An integral electronic barometer
automatically corrects the flash point value in accordance with the mandated
equation that is included in all flash point methods. The
result and key test parameters are shown on the display and may be transferred
via an integral RS232 interface
to a printer or external computer. When connected to a printer the test report
includes a sequential test number
and identification. The last test result is stored in the instrument and may be
accessed from the control panel. INTEGRAL DRAUGHT SCREEN An opening transparent draught screen and a fixed stainless steel rear screen is provided with each module. The screens assist in obtaining consistent and accurate results even when the MultiFlash is used in air conditioned laboratories or under a fume hood. The transparent screen also functions as a safety screen for the operator. IN-BUILT SAFETY In the event of instrument over-temperature 3 independent safety systems are automatically activated. The power supply to the heating elements is isolated, the gas supply to the igniter is shut off, and the cooling fan is switched on to reduce the cup temperature. RELIABLE OPERATION AND EASE OF SERVICE MultiFlash is designed to provide long and reliable operation. Maintenance requirements are limited to replacement of service components, such as the igniter, which is inexpensive and quickly fitted.
Cleveland Open Cup TAG Module Small Scale Module
Lazar Scientific, Petroleum Test, flash point, Pensky Marten, TAG Closed Cup, Cleveland Open Cup, small-scale flash, cfr49, 49cfr, DOT, epa1020, setaflash, ink, food, paint, coating Lazar Scientific, Petroleum Test, flash point, Pensky Marten, TAG Closed Cup, Cleveland Open Cup, small-scale flash, cfr49, 49cfr, DOT, epa1020, setaflash, ink, food, paint, coating |