90000-2 SETA OIL TEST CENTRIFUGE

ASTM D91; D96; D893; D1290; D1796; D1966; D2273; D2709; D2711; D4007; IP 75 (Obs); IP 359; BS 2882 (Obs); ISO 374; ISO 9030; 
DIN 51 793;
NF M07-020; FTMS 791b Methods 3000; 3003; 3004; 3101; 3121; 5661; API 2542; API 2548; API MPMS Chapter 10.3

bullet

Conforms to safety requirements EN6101-2-020

bullet

4 place swing out rotor

bullet

Static, near vertical bucket positioning

bullet

Specifically designed for testing oils

bullet

Heated chamber, ambient to 70°C

bullet

Universal buckets for 6 and 8 inch glassware

bullet

Optional ‘Setafuge’ Hazard Reduction System

bullet

Microprocessor control with 9 memories

centrifuge.jpg (80806 bytes) (click on picture to enlarge)

Seta Oil Test Centrifuge is a microprocessor controlled, heated centrifuge manufactured exclusively for Seta by Hermle Labortechnik. The instrument is fully programmable allowing automatic configuration to the specified oil test parameters.  A four place swing out rotor and universal bucket assembly accommodates low cost adaptors and cushions suitable for borosilicate glass centrifuge tubes of the types specified for oil testing: 6 or 8 inch conical, 8 inch trace sediment or 8 inch pear-shaped.  To reduce errors in measurement of tube content, the rotor design allows tubes to stand in a near upright (vertical) position at rest.  Speed, temperature, and timing are microprocessor controlled and run parameters are entered via the panel controls and digital displays.  Speed can be specified and measured in either RPM (rotational speed) or RCF (relative centrifugal force) mode and 9 run profiles can be stored in memory. The run duration can be set between 1 and 60 minutes in one-minute increments, or set for continuous operation. A ‘Quick Run’ mode is also provided. The braking time is programmable between 30 and 110 seconds.  A controlled isothermal band heater holds the temperature between 30 and 70°C ±1°C, and is programmed to compensate for friction heating effects during operation thus ensuring correct sample temperatures throughout the test.  A brushless asynchronous motor ensures high reliability with low maintenance and the centrifuge has in-built error messaging diagnostics.

SAFETY features include a motor driven lid latch with a safety interlock to prevent centrifuge operation while the lid is unlocked, imbalance detection, and over-temperature protection for both the motor and the chamber. The centrifuge is almost silent in operation with measured noise levels below 65 dB (A).  Two types of trolleys are available as optional accessories to allow easy movement of the instrument. The centrifuge meets the requirements of EN 61010-2-020; DIN 58970 parts 1, 2 & 4; and UVV VBG 7z.

SUPPLIED WITH: rotor, buckets and cushions.

Note: Bucket adaptors and tubes should be selected from the method table according to test method requirements.

ACCESSORIES - CENTRIFUGE

REQUIRED
Choose adaptors and tubes from the following options,
dependant on the method of test (See Table Below):

90001-2: ADAPTOR, for 90040-0 and 90060 glassware (pack of 4) 
90003-2: ADAPTOR CUSHION, for 90050-0 glassware (pack of 4)
90005-2: ADAPTOR, for 90011-0 glassware (pack of 4)
90011-0: TUBE, 100ml cone-shaped, 6 inch, graduated to
0.05ml (pack of 6)
90040-0: TUBE, 100ml cone-shaped, 8 inch, graduated to
0.05ml (pack of 6)
90050-0: TUBE, 100ml pear-shaped, 8 inch, tube tip
graduated to 0.01ml over the range 0 to 0.2ml (pack of 6)
90060-0: TUBE, 100ml trace-sediment, graduated to
0.005ml at tube tip (pack of 6)

Other items which may be required include: Funnel, Demulsifier, Solvents, Pipette, Stirrer, Desiccator,

OPTIONAL

90010-0: ‘SETAFUGE’ HAZARD REDUCTION SYSTEM
90014-0 LOW TROLLEY, for centrifuge, with lockable
castors, height 68cm with centrifuge
90015-0 HIGH TROLLEY, for centrifuge, with lockable
castors, height 99cm with centrifuge
90016-0 TRANSFORMER, for 110/120V 60Hz operation
90200-4: WATER BATH, ambient to 80°C, for pre-heating
samples (alternative to 90300-0)
90300-0: SETA BLOCK HEATER, for use with 90301-0 to
dry heat tubes
90301-0: BLOCK, aluminum, to hold up to four 90040-0 or
90060-0 tubes
90202-2: RACK, 6 place for 90011-0 tubes
90203-2: RACK, 6 place for 90040-0 and 90060-0 tubes
90204-2: RACK, 4 place for 90050-0 tubes
90041-2: STOPPERS (Pack of 50)
99100-2 ANALYTICAL BALANCE, for ASTM D893

Items Recommended For Each Test Method

SETA No. D91 D96 D893 D1796 D2273 D2709 D2711 D4007
90040-0 X X X X X X
90050-0 X
90060-0 X X
90011-0 X
90010-0 X X X X X X X X
90001-2 X X X X X X X X
90003-2 X
90005-2 X
90041-2 X X X X X X X X
90202-2 X
90203-2 X X X X X X X X
90204-2 X
90301-0 X X X X X X X X
90200-4 or 90300-0 X X X X X X X X
Relative Centrifugal Force (rcf)
90040-0 600-700 x g 500 x g 600-700 x g 500-800 x g 700 x g 600 x g
90050-0 800 x g
90060-0 600-700 x g 800 x g
90011-0 500 x g
Sample Pre-Heat Temperature 32 to 35șC 60 +/-3șC 60 +/-5șC 49 +/-1șC
or 60 +/-1șC
32 to 35șC 82 +/-1șC 60 +/-3șC
Test Temperature Unheated 60 +/-3șC Unheated 60 +/-1șC Unheated 21 to 32șC 60 +/-1șC 60 +/-3șC
Test Time 10 mins. 5 mins. 20 mins 10 mins. 10 mins. 10 mins. 10-15 mins. 10 mins.